Mechanical installation
Standard devices in a power range of 0.25 ... 3 kW
Assembly without filter in "standard" technique
5
l
89
EDS84ASC552 EN 8.1
Assembly without filter in "standard" technique
For mounting, use two screws M5 x >10 mm. The mounting location and material must
ensure a durable mechanical connection.
ƒ Screw and washer assemblies or hexagon socket screws with washers are
recommended.
How to proceed:
1. Prepare the fixing holes on the mounting surface.
2. Screw the controller directly to the mounting surface.
StateLine, HighLine
8400GG105m
Fig. 5−1 Device dimensions
h b t h
1
h
2
t
1
g
1
g
2
g
3
[kW] [mm]
E84AVxxE2512xXx
0.25
165 70 199 194 235 186 6 11 12
E84AVxxE3712xXx
0.37
E84AVxxE3714xXx
0.37
215 70 199 244 285 186 6 11 12
E84AVxxE551xxXx
0.55
E84AVxxE751xxXx
0.75
E84AVxxE112xxXx
1.1
270 70 199 304 340 186 6 11 12
E84AVxxE152xxXx
1.5
E84AVxxE222xxXx
2.2
E84AVxxE3024xXS
3.0
E84AVxxE2512xBx
0.25
165 70 219 194 235 206 6 11 12
E84AVxxE3712xBx
0.37
E84AVxxE3714xBx
0.37
215 70 219 244 285 206 6 11 12
E84AVxxE551xxBx
0.55
E84AVxxE751xxBx
0.75
E84AVxxE112xxBx
1.1
270 70 219 304 340 206 6 11 12
E84AVxxE152xxBx
1.5
E84AVxxE222xxBx
2.2
E84AVxxE3024xBS
3.0
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com