Loading...
Braking operation
Operation with spring−applied brake
Rated data
8
l
251
EDS84ASC552 EN 8.1
ƒ Integrated brake control for devices of the HighLine/TopLine version
Range Values
Input voltage DC 24 V in accordance with IEC 61131−2
19.2 ... 28.8 V
Input current DC 0.1 ... 2.6 A
Output voltage DC 24 V
Maximum brake current DC 2.5 A
Internal control Information on internal brake control is provided in the software manual for the
Inverter Drives 8400 HighLine C / TopLine C.
Maximally connectable
cable cross−section
1.5 mm
2
AWG 16
, Further technical data regarding the brake control can be found in chapter
4.7.7.