Braking operation
Operation with spring−applied brake
Rated data
8
l
250
EDS84ASC552 EN 8.1
8.3.2 Rated data
ƒ E82ZWBRB brake switch
Range Values
Input voltage 1/N/PE AC 230 V (AC 180 ... 264 V), 45 ... 65 Hz
2/PE AC 230 V (AC 180 ... 264 V), 45 ... 65 Hz
Input current AC 0.1 ... 0.54 A
Output voltage
DC 205 V at AC 230 V mains voltage
Maximum brake current
DC 0.41 A Installation in 8200 motec
DC 0.54 A Installation in control cabinet
Control input
Control voltage
DC 24 V, PLC−level
HIGH
LOW
DC +15 ... 30 V
DC 0 ... +3 V
Control current 5 ... 10 mA
Protective function Protected against polarity reversal until DC 60 V
Maximally connectable cable
cross−section
1.5 mm
2
AWG 16
ƒ E82ZWBRE brake switch
Range Values
Input voltage 3/PE AC 400 V (AC 320 ... 550 V), 45 ... 65 Hz
Input current AC 0.1 ... 0.61A
Output voltage
DC 180 V at AC 400 V mains voltage
DC 225 V at AC 500 V mains voltage
Maximum brake current
(pilot duty)
DC 0.47 A Installation in 8200 motec
DC 0.61 A Installation in control cabinet
Control input
Control voltage
DC 24 V, PLC−level
HIGH
LOW
DC +15 ... 30V
DC 0 ... +3 V
Control current 5 ... 10 mA
Protective function Protected against polarity reversal until DC 60 V
Min. permissible switch−off
time
t
off
>20ms
Maximally connectable cable
cross−section
1.5 mm
2
AWG 16
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com