Mechanical installation
Standard devices in a power range of 30 ... 45 kW
Filter mounting variant
5
l
146
EDS84ASC552 EN 8.1
E84ZESx008
Proceed as follows for installation:
1. Prepare threaded holes on the mounting plate.
2. Equip threaded holes with screws and washers.
Use 8 screw and washer assemblies or hexagon socket screws with washers.
Do not fully tighten the screws.
3. Mount the filter onto the prepared mounting plate.
Only tighten the screws hand−tight.
4. Mount the standard device onto the prepared mounting plate.
Only tighten the screws hand−tight.
5. If required, pre−assemble further units.
6. Adjust all units.
7. Screw all units onto the mounting plate.