EasyManua.ls Logo

Lenze 8400 HighLine C - Page 24

Lenze 8400 HighLine C
286 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product description
Overview of control terminals
3
l
24
EDS84ASC552 EN 8.1
Control terminals for devices in the TopLine version
8400TLC032b
Connection Information
Pos. Description TopLine C
X1 CANopen connection
^ 206
S1
CANopen settings
Settings for CANopen terminating resistor and axis bus
X3 Analog inputs / outputs; 10 V reference voltage ^ 222
X4
Digital inputs; controller enable
24 V supply of the control electronics
Digital outputs
^ 225
^ 225
24 V voltage output
X5
Digital inputs; controller enable
^ 224
External 24 V supply of the control electronics; internal 24 V supply, fused
via PTC
X6 (DIAG) Diagnostic interface ^ 214
X7 Resolver ^ 228
X8 Encoder ^ 229
X10 Axis bus ^ 230
X107
24 V brake supply
^ 227
+ BD1
Connection for DC brake coil
− BD2
MMI Slot for memory module (Memory Module Interface) ^ 275
2 Icon Description
{
Long discharge time: All power terminals remain live for a few minutes after mains
disconnection! The duration is given under the warning symbol on the device.
}
High leakage current: Carry out fixed installation and PE connection according to EN 61800−5−1!
'
Electrostatic sensitive devices: Before working on the device, the personnel must be free of
electrostatic charge!
|
Hot surface: Risk of burns! Hot surfaces should not be touched without wearing protective
gloves.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com