EasyManua.ls Logo

Lenze 8400 HighLine C - Page 39

Lenze 8400 HighLine C
286 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
Rated data
Operation at rated mains voltage 400 V
4
l
39
EDS84ASC552 EN 8.1
4.2.3 Operation at rated mains voltage 400 V
Basis of the data
Mains Voltage Voltage range Frequency range
U
Lrated
[V] U
Lrated
[V] f [Hz]
3/PE AC 400 320 − 0 % ... 440 + 0 % 45 − 0 % ... 65 + 0 %
Mains current at I
aN
Apparent output power Motor power
with external
mains choke
without external
mains choke
U, V, W 4 pol. ASM
Type I
LR
[A] I
LR
[A] S
aR
[kVA] P
aR
[kW]
E84AVxxx3714 1.4 1.8 0.8 0.37
E84AVxxx5514 2.2 2.7 1.1 0.55
E84AVxxx7514 2.5 3.6 1.5 0.75
E84AVxxx1124 3.2 4.4 2.0 1.1
E84AVxxx1524 3.9 5.5 2.4 1.5
E84AVxxx2224 5.1 7.3 3.5 2.2
E84AVxxx3024xxS 7.0 9.8 4.6 3.0
E84AVxxx3024xx0 7.0 9.8 4.6 3.0
E84AVxxx4024 8.8 13.1 5.9 4.0
E84AVxxx5524 12.0 18 8.1 5.5
E84AVxxx7524 15.0 20.0 10.3 7.5
E84AVxxx1134 21.0 29.0 14.7 11.0
E84AVxxx1534
1)
29.0 20.0 15.0
E84AVxxx1834 36.0 50.4 24.9 18.5
E84AVxxx2234
1)
42.0 29.3 22.0
E84AVxxx3034
1)
55.0 38.0 30.0
E84AVxxx3734
1)
68.0 47.4 37.0
E84AVxxx4534
1)
80.0 55.5 45.0
1)
only with external mains choke
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com

Table of Contents

Related product manuals