EasyManua.ls Logo

Lenze 8400 HighLine C - Page 50

Lenze 8400 HighLine C
286 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
Rated data
Operation at a rated mains voltage of 500 V
4
l
50
EDS84ASC552 EN 8.1
Rated data for internal brake chopper
Switching threshold V
BRmax
: 790 V, adjustable
R
Bmin
[]
I
BRmax
[A]
P
BRmax
[kW]
I
BRd
[A]
P
Bd
[kW]
t
Z
[s]
t
on
[s]
t
fp
[s]
Type
E84AVxxx3714 390
2.0 1.6 2.0 1.6
E84AVxxx5514 390 2.0 1.6 2.0 1.6
E84AVxxx7514 390 2.0 1.6 2.0 1.6
E84AVxxx1124 180 4.4 3.5 4.4 3.5
E84AVxxx1524 180 4.4 3.5 4.4 3.5
E84AVxxx2224 150 5.3 4.2 5.3 4.2
E84AVxxx3024xxS 82 9.6 7.6 9.6 7.6
E84AVxxx3024xx0 82 9.6 7.6 9.6 7.6
E84AVxxx4024 47 16.8 13.3 13.0 10.3
E84AVxxx5524 47 16.8 13.3 13.0 10.3
E84AVxxx7524 27 29.3 23.1 29.3 23.1
E84AVxxx1134 27 29.3 23.1 29.3 23.1
E84AVxxx1534 18 43.9 34.7 43.9 34.7
E84AVxxx1834 15 52.7 41.6 52.7 41.6
E84AVxxx2234 15 52.7 41.6 52.7 41.6
E84AVxxx3034 7.5 105.3 83.2 105.3 83.2
E84AVxxx3734 7.5 105.3 83.2 105.3 83.2
E84AVxxx4534 7.5 105.3 83.2 105.3 83.2
R
Bmin
Minimum brake resistance, nominal value ±10 %
I
BRmax
Peak current
P
BRmax
Peak braking power
I
BRd
Continuous current RMS − important for the dimensioning of the cables
P
Bd
Continuous braking power
t
Z
Cycle time, periodic load change with running time and recovery time
t
on
Running time
t
Z
− t
on
Recovery time
t
fp
Maximum running time without initial load and compliance with the recovery
time
Note on brake chopper operation according to cUL/CSA
Brake chopper operation according to cUL/CSA is ensured if the running time t
on
is not
higher than 30% compared to the cycle time t
z
.
The condition is fulfilled if the continuous braking power P
d
is not higher than 30%
compared to the peak braking power P*
BRmax
made possible through the resistor R
B
used:
t
on
t
z
v 0.3;
P
d
P
:
BRmax
v 0.3; P
:
BRmax
+
U
BRmax
2
R
B
R
B
Brake resistor used (nameplate data)
V
BRmax
Switching threshold of the inverter (725 V at V
LN
= 400 V, 790 V at V
Lr
= 500 V)
VLr Rated mains voltage
P*
BRmax
Peak braking power of the resistor used
P
d
Continuous braking power of the load to be braked (dependent on the
application)
t
on
Running time
t
Z
Cycle time ("duty cycle")
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com

Table of Contents

Related product manuals