Lenze · EMF2180IB communication module (EthernetCAN) · Communication Manual · DMS 5.1 EN · 09/2016 · TD17 37
6 Commissioning
6.2 Commissioning with the web server
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.2.1 Assigning a fixed IP address
Start your web browser and then enter the communication module's IP address that is known to you
as URL (instead of "xxx.xxx.xxx.xxx"):
2180FEW010
The web interface of the communication module will appear. Here you can carry out all further
settings.
2180FEW011
Note!
The Lenze standard setting of the IP address is ’0.0.0.0’. With this (invalid) IP address, the
communication module at the start automatically finds its own IP address in the range
of ’169.254.xxx.xxx’ on the basis of the standardised APIPA process.