8 Drive Profile (Fieldbus)
NETword Configuration
116 Lenze · Inverter i510 / i550 - Cabinet · Operation Manual · 0.4 EN · 02/2016
P420:21
0x2634:21
NETWordOUT1 - bit 11
i510
i550
R/W
78:At current limit
(Reference see P420:1)
Function of Network Bit 11 (SW 02.01: New Default)
P420:22
0x2634:22
NETWordOUT1 - bit 12
i510
i550
R/W
71:Actual speed = 0
(Reference see P420:1)
Function of Network Bit 12 (SW 02.01: New Default)
P420:23
0x2634:23
NETWordOUT1 - bit 13
i510
i550
R/W
69:Inverse rotation
(Reference see P420:1)
Function of Network Bit 13 (SW 02.01: New Default)
P420:24
0x2634:24
NETWordOUT1 - bit 14
i510
i550
R/W
115:Holding brake release
(Reference see P420:1)
Function of Network Bit 14 (SW 02.01: New Default)
P420:25
0x2634:25
NETWordOUT1 - bit 15
i510
i550
R/W
55:Safe Torque Off
(Reference see P420:1)
Function of Network Bit 15 (SW 02.01: New Default)

Table of Contents