3 Product description
General
Lenze · Inverter i510 / i550 - Cabinet · Operation Manual · 0.4 EN · 02/2016 13
3.1.1 i500 inverter types
i510
i550
Performance data
Mains: 1 AC 230 V or
(1/3 AC 230 V planed)
0.25 to 2.2 kW
0.25 to 2.2 kW
Mains: 3 AC 400/480 V
0.37 to 2.2 kW
0.37 to 45.0 kW
(Planned up to 110.0 kW)
Overload ability
150% / 60s and 200% / 3s
Interfaces
Digital inputs/outputs (5/1), analog inputs/outputs (2/1), relays
(optional extension with i550)
External 24 V supply
PTC thermal contact input
HTL incremental encoder (100 kHz)
CANopen, Modbus
CANopen, Modbus, PROFIBUS, Ether-
CAT, PROFINET, EtherNet/IP
Integrated brake chopper
DC bus connection (3 AC 400V devices)
Approvals
CE, EAC
UL & cUL (up to 22 kW, further approvals in progress)
RoHS2, IE2 in accordance with EN 50598-2
Functions
V/f controls (linear, quadratic) Sensorless vector control
DC injection Braking
Compound Braking
Mechanical Brake management low-wear brake control
Dynamic braking through brake re-
sistance
PID controller, Motor potentiometer, Flying restart
Safety technology
Safe torque off (STO)

Table of Contents