9 Troubleshooting
Error messages
Lenze · Inverter i510 / i550 - Cabinet · Operation Manual · 0.4 EN · 02/2016 121
0x2383
9091
Warning
ixt Warning
Ixt warning
0x2387
9095
Error
Clamp timeout
Clamp responded too often
0x3120
12576
Error
Mains Phase fail
Main single phase fault
0x3210
12816
Error
DC Bus OV
DC link circuit overvoltage
0x3211
12817
Warning
Warn.DC Bus OV
DC link circuit overvoltage warning
0x3220
12832
Trouble
DC Bus UV
DC link circuit undervoltage
0x3221
12833
Warning
Warn.DC Bus UV
DC link circuit undervoltage warning
0x3222
12834
Warning
DC Bus on-UV
DC link voltage to low for power up
0x4210
16912
Error
PU Overtemp.
Power module overtemperature fault
0x4281
17025
Warning
Heats. fan error
Heat sink fan fault. Check heat sink fan
0x4285
17029
Warning
Warn.PU Overtemp
Power module overtemperature warning
0x4310
17168
Configurable
Overtemp. motor
Motor temperature has reached error level.
(P309:2)
0x5112
20754
Warning
24V supply low
24V supply level critical
0x5380
21376
Error
Incomp. OEM HW
Control Unit HW OEM Type is not compatible with
Power Unit HW OEM Type
0x6010
24592
Warning
Watchdog timeout
Watchdog time-out
0x618A
24970
Warning
Int. fan error
Internal fan fault
0x6280
25216
Error
P400 config err
Connection list wrong connected.
Start forward/reverse an Run forward/reverse
can't be used together.
In Flexible control mode Inverter enable or
Run/Stop must be assigned to a I/O. (Exception:
Inverter is controlled from network, Network ena-
ble (P400:37) is HIGH)
0x6281
25217
Error
User fault 1
User fault 1 (Defined in P400:43)
0x6282
25218
Error
User fault 2
User fault 2 (Defined in P400:44)
0x6290
25232
Warning
Invert rotation
Reverse direction protection warning. (P304:0)
0x6291
25233
Error
Trouble overflow
Maximal allowed troubles exceeded. (P760:2-5)
0x62A0
25248
Error
AC User fault
AC control user fault
0x62A1
25249
Error
Netw.UserFault 1
Network user fault 1
0x62A2
25250
Error
Netw.UserFault 2
Network user fault 2
0x62B1
25265
Error
NetwordIN1 error
NetwordIN1 duplicate bit connection fault
0x7080
28800
Error
Assertionlevel
Last setting of Assertion level is different to stored
parameter.
Check setting of P410:1, save parameters and re-
boot inverter.
0x7081
28801
Configurable
AI1 monitoring
Analog input 1 fault (P430:8-10)
0x7082
28802
Configurable
AI2 monitoring
Analog input 2 fault (P431:8-10)
0x70A1
28833
Warning
AO1 monitoring
Analog output 1 fault
0x70A2
28834
Warning
AO2 monitoring
Analog output 2 fault
0x7121
28961
Error
Pole posi error
Pole position identification fault
0x7180
29056
Configurable
Mot max current
Motor over current. (P353:1-2)
0x7385
29573
Warning
F.fdb spd limit
Feedback system: speed limit
0x7580
30080
Configurable
Diag TX error
Diagnosis transmit message ring buffer error
(0x218B:0)
0x7581
30081
Configurable
Diag RX error
Diagnosis receive message ring buffer error
(0x218B:0)
0x7680
30336
Warning
EPM full
There are to many parameters on the EPM.