Starting up the device – webConfig tool
Leuze electronic GmbH + Co. KG BPS 307i 67
• Error handling procedures
Parameters for the position value in case of failure.
Configuration of position monitoring (DATA PROCESSING tab, Position > Monitoring)
• Position limit value1/2
Signals that the position value is outside of the configured limit value range.
Configuration of speed detection (DATA PROCESSING tab, Speed > Detection)
• Speed measurement averaging
Measurement value preparation averages all speed values calculated during the selected period (aver-
aging) to yield a speed output value.
• Scaling free resolution
Free scaling of the output of the speed values.
• Error handling procedures
Parameters for the speed value in case of failure.
Configuration of speed monitoring (DATA PROCESSING tab, Measurement data > Speed >
Monitoring)
• Speed limit value1-4
Signals that the speed is outside of the configured limit value range.
Configuration of the measurement value display (DATA PROCESSING tab, General preparation)
• Unit of measurement: metric or inch
• Counting direction
Count direction for position calculation or sign for speed calculation.
• Output mode sign
Output mode of the sign. Affects position value and speed output.
Configuration of monitoring of the reading quality (DATA PROCESSING tab, Reading quality)
• Warning threshold for reading quality in%
• Error threshold for reading quality in%
Configuration of the communication data (COMMUNICATION tab)
• Configuration of the SERVICE USB interface
• Selection of the master clock frequency according to the request frequency of the control (master):
• 80kHz - 600kHz
• 50kHz - 79kHz
• Update rate of the measurement values on the SSI interface. The measurement value is updated inde-
pendent of the clock frequency.
• 2ms
• 1ms
• 200µs
• 50µs