Technical data of BPS 8
Leuze electronic BPS 8 12
TNT 35/7-24V
Table 3.1: General specifications
Environmental data
Operating temperature range 0 °C -40 °C
Storage temperature range -20 °C -60 °C
Air humidity Max. 90% rel. humidity, non-condensing
Vibration IEC 60068-2-6, test Fc
Shock/continuous shock IEC 60068-2-27, test Ea
Electromagnetic compatibility EN 61000-6-2:2005+AC:2005,
EN 61000-6-3:2007+A1:2011+AC:2012
Conformity CE, CDRH
Certifications
1)
2)
UL 60950-1, CSA C22.2 No.60950-1
Bar code tape
Max. length (measurement
length)
10,000 m
3)
Ambient temperature -40 °C -120 °C
Mech. properties Scratch and wipe resistant, UV resistant,
moisture resistant, partly chemical resistant
1) For UL applications: use is permitted exclusively in Class 2 circuits according to NEC
2) These sensors shall be used with UL Listed Cable assemblies rated 30V, 0.5A min, in the
field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)
3) Depends on the transmission protocol and on the configured resolution.