Page 35
INSTALLER SETUP
This section describes the items that the installer must setup as part of system installation. The Installer Setup mode
is used to configure the general operation of the system, the Outputs, the Zone Types, the Digital Communicator, and
various other settings. This information is covered only in this manual. All other SETUP items, including delay times,
names and voices, voice dialer, and codes are covered in the Omni LTe Owner's Manual, Document No. 20R00-70.
SETUP items are stored permanently in the system, even if the battery and AC power are disconnected. The default
settings are the ones that have been set at the factory. You can review or change the setup items, as shown:
Note: The default Installer Code is 1111.
To access the SETUP menu, press the 9 key and enter the installer code. To access the INSTALLER SETUP menu,
press the # (INST) key.
INSTALLER SETUP MENU:
1=CTRL 2=ZONE 3=DCM
5=TEMP 6=MISC 7=EXP
8=ZOPT
SETUP CONTROL
To configure X-10, UPB, voltage outputs, and Vizia RF Z-Wave options, from the Installer Setup menu, select the 1
(CTRL) key. The output type for both the interior and exterior horns may also be changed.
Press () to advance to the next item, () to go back.
X-10 HOUSE CODE
The base X-10 house code must be specified. The base house code is the house code for units 1-16 and is
referenced as House Code 1. The house code for the units 17-32 is the next house code after the base house code,
or house code "B" if the base house code is "A".
X-10 HOUSE CODE: A
1-16=A-P
UPB NETWORK ID
The Network ID is a unique number between 1 and 255 which identifies your UPB Network.
UPB NETWORK ID: 1
1-255
Enter the UPB Network ID (1-255) followed by the ' # ' key.
UPB PASSWORD:
The Network Password is a 4-digit number between 0001-FFFF that is used to protect your UPB network from
unauthorized changes to the internal settings of your UPB devices.
UPB PASSWORD: 1234
0000-FFFF
Enter the UPB Password (0000-FFFF) followed by the ' # ' key.
To enter the digits A-F, first press the “OFF” key, then press the 0-5 key respectively.