SETUP EXPANSION
To configure the serial address, the function for each of the serial ports, and access control readers, from the Installer
Setup menu, press the 7 (EXP) key.
SERIAL ADDRESS
The Serial Address when multiple controllers are connected to one PC.
Note: If only one controller is connected to a PC running PC Access software, the Serial Address must be set to "0".
SERIAL 1 RATE
The "Serial 1 Rate" selects the baud rate used for the first built-in serial interface (J1 Serial) on the Omni LTe
controller. Select the baud rate for the first built-in serial interface from the list. Use the arrow keys to select the baud
rate then press the ' # ' key.
BAUD RATE NUMBER
75 baud 1
150 baud 2
300 baud 3
600 baud 4
1200 baud 5
2400 baud 6
4800 baud 7
9600 baud 8 (default)
SERIAL 1 FUNCTION
The "Serial 1 Function" selects the communication protocol used for the first built-in serial interface (J1 Serial) on the
Omni LTe controller. Select the function for the first built-in serial interface from the list. Use the arrow keys to select
the function then press the ' # ' key.
FUNCTION TYPES NUMBER DESCRIPTION
OMNI-LINK 3 Serial communication using the Omni-Link protocol
PRO-LINK 4 Serial communication using the Pro-Link protocol
UPB 5 Serial communication using the UPB protocol
VIZIA RF Z-WAVE 10 Serial communication using the Z-Wave protocol
LEVITON HI-FI 11 Serial communication using the LEVITON Hi-Fi protocol
LEVITON HI-FI 2 26 Serial communication using the LEVITON Hi-Fi 2 protocol
ACCESS CONTROL 18 Serial communication the using LEVITON Access Control protocol
CLIPSAL C-BUS 21 Serial communication using the Clipsal C-Bus protocol
DYNALITE 22 Serial communication using the Dynalite protocol
ZIGBEE 27 Serial communication using the ZigBee protocol
COOLMASTER 28 Serial communication using the CoolMaster protocol
KNX 29 Serial communication using the KNX Gateway protocol
SERIAL 2 – SERIAL 5 RATE
The "Serial 2 Rate" - “Serial 5 Rate" selects the baud rate used for the second, third, fourth, and fifth built-in serial
interface ports (J2 Serial - J5 Serial, respectively) on the Omni LTe controller. Select the baud rate for each built-in
serial interface from the list.
SERIAL 2 – SERIAL 5 FUNCTION
The "Serial 2 Function" – “Serial 5 Function” selects the communication protocol used for the second third, fourth, and
fifth built-in serial interface ports (J2 Serial – J5 Serial, respectively) on the Omni LTe controller. Select the function
for each built-in serial interface from the list.