To disable the automatic test, press the ' # ' key and then 0 for Never, and ' # '.
TEST CODE: 98
0-FF
ALARM CODES (4/2 and 3/1 Formats)
Press the down arrow () to advance to the next ZONE ALARM CODE. Press the up arrow () to go to the previous
ZONE ALARM CODE. To change an alarm code, enter two digits for 4/2 format, or one digit when using 3/1 format,
then press the ' # ' key.
Enter the 2 digit alarm code (1 digits if using 3/1 format) and press ' # '. To enter the digits B-F, first press the OFF
key, then press the 1-5 key respectively (i.e. B1 = OFF 1 1 # and CB = OFF 2 OFF 1 #).
The various alarm codes are sent when the indicated alarm zone is tripped. Each alarm code must be two digits long
for 4/2 format (01-FF), 1 digit for 3/1 format (1-F).
To disable the digital communicator for a specific zone, set the alarm code to 0 or 00. The digital dialer will not report
when this zone is tripped.
ZONE 1 ALARM CODE: 01
0-FF
THROUGH
USER 16 CLOSE CODE: 76
0-FF
↑
SETUP TEMPERATURES
To configure temperatures from the Installer Setup Menu, press the 5 (Temp) key.
TEMPERATURE DISPLAY
This allows you to choose between Fahrenheit and Celsius temperature format.
TEMPERATURE DISPLAY: 1
1=FAHRENHEIT 2=CELSIUS
↓
THERMOSTAT TYPE
If Omnistat thermostats are part of the system, this item specifies the thermostat type for each thermostat (this
enables the thermostat). If thermostats are used, they must be configured to the applicable thermostat type. When
any THERMOSTAT TYPE is changed from the default setting of "Not Used", Zone 16 and Output 8 is automatically
configured for thermostats. There is no need to change the ZONE TYPE for Zone 16 or OUTPUT TYPE for Output 8.
For thermostat types, the current setting is shown on the bottom line.
THERMOSTAT 1 TYPE: 0
NOT USED #=CHNG
THROUGH
THERMOSTAT 4 TYPE: 0
NOT USED #=CHNG ↑