SIA CP-01 COMPLIANCE
This control complies with the SIA CP-01 Control Panel Standard - Features for False Alarm Reduction.
CP-01 is a standard sponsored by the Security Industry Association (SIA) designed with features for security systems
and associated arming and disarming devices intended to reduce the incidence of false alarms.
PROGRAMMABLE FEATURES
SHIPPING DEFAULTS AND RECOMMENDED PROGRAMMING
For full or auto arming: 45-
180 seconds
Progress Annunciation - Disable
(Audible Exit Delay)
Individual consoles may be
disabled
For re-entry during exit
delay
Required Option
(except for remote arm)
If no exit after full arm
Abort Window for Non-Fire Zones
(Dial Out Delay – Zone Option)
Abort Window Time
(Dial Out Delay)
Abort annunciation
(Alarm Aborted)
Display that alarm was
aborted
Cancel Window
(Alarm Reset Time)
Cancel annunciation
(Alarm Canceled)
Display that alarm was
canceled
Duress Feature
(Duress Code)
No duplicates with other
user codes
Cross Zoning
(Cross Zoning – Zone Option)
Enabled and two (or
more) zones
programmed
Programmable Cross Zoning Time
(Cross Zone Window)
Time based on walk
path in protected area
Swinger Shutdown
(Swinger Shutdown Number)
For all non-fire zones, shut
down at 1 or 2 trips
Swinger Shutdown Disable
(Swinger Shutdown – Zone
Option)
For non-police response
zones
Enabled unless
sensor can self verify
Depends on user phone line
Enabled if user has
call waiting
* Programmable at installation may be subordinate to other UL requirements for the intended application.
** Combined Entry Delay and Abort Window (Dial Out Delay) should not exceed 1 minute.
Minimum Equipment Requirements for a CP-01 Compliant Installation:
Model 20A00-70, 20A00-72, 20A00-73