TWO-WAY AUDIO
If a Two-Way Audio Module is being used, this item enables hands free audio communication between your
customer's premises and the central station.
After the transmission of the alarm to the central station, the operator can talk and listen to people and sounds at the
premises.
TWO-WAY AUDIO: 0
0=NO 1=YES
If a Two-Way Audio Module is part of the system, select the 1 (YES) key to enable this feature.
REPORT OPEN/CLOSE
The communicator can be setup to send an opening and a closing report by user code. Whenever the system is
disarmed the communicator will send an opening report to the central station. When the system is armed, the
communicator will send a closing report to the central station.
REPORT OPEN/CLOSE: 0
0=NO 1=YES
To enable the communicator to send opening and closing reports to the central station, select the 1 (YES) key.
REPORT BYPASS / RESTORE
This item is used to enable/disable reporting to the central station when a zone is bypassed or restored when using
Contact ID. The communicator can be configured to send bypass/restore signals to the central station when using
Contact ID. Whenever a zone is bypassed, the communicator will send a zone bypassed report to the central station.
When a zone is restored, the communicator will send a zone restored report to the central station.
REPORT BYPASS/REST: 1
0=NO 1=YES
To disable the communicator from sending bypass and restore reports to the central station, select the 0 (NO) key.
AC Fail Report Time
The AC Fail Report Time is used to suspend the “AC Power Off” trouble report to the central station, until the power
has been off for the specified amount of time. This is used to prevent the Omni LTe from calling and reporting of AC
power failures when there are numerous AC power interruptions at the premises. An “AC Power Off” trouble is not
generated until power has been off for 3 minutes. The AC Fail Report Time begins after the trouble has been
generated (i.e. 3 minutes after the AC power goes off) and is reset every time power is restored.
AC FAIL REPORT TIME: 60
0-240 MIN 0=DISABLE
The AC Fail Report Time can be set from 1 to 240 minutes, or disabled (trouble will not be reported).
AUTOMATIC TEST TIME
The communicator CAN be setup to automatically send a test code to the central station on a periodic basis.
AUTOMATIC TEST TIME is used to set the time and days of the week of the test, and the TEST CODE specifies the
code that will be transmitted for the test.
AUTOMATIC TEST TIME:
-- NEVER #=CHNG