INSTALLATION & SERVICE MANUAL EASYLIFT UK VERS 1.5
Liftup A/S Hagensvej 21| DK-9530 Støvring | Denmark | T: +45 96 86 30 20 | M: support@liftup.dk | www.liftup.dk | CVR DK-1015 3964
3. In the Stroke area, set the value of actuators:
- Platform Lifting height, in mm (see NOTE)
4. Push the “Write system parameters to device”.
Now the system is ready to run, please remember to check that all settings are as expected.
NOTE: Remember to deduct approx. 70 mm to your settings as the platform is approx. 70 mm
thick.
IMPORTANT! After programming the system must be calibrated by pushing the
lift down” button until the platform is positioned at lower landing.