9. Actuator replacement
9.1 Dismounting actuator
ATTENTION! When the actuators are dismounted, the side covers are not
supported.
1.
Push “lift down” button until the platform is
positioned at lower landing.
2.
Push the emergency stop button.
3.
Remove top cover from the frame.
4.
Disconnect the cable for the actuator.