MMX6x2-HT
User’s Manual
Section 8. LW3 Programmers’ reference Page 97 / 119
8.7.2. BAUD rate setting
Command format
SET/MEDIA/UART/<Pn>.Baudrate=0|1|2|3|4|5|6|7
Response format
pw/MEDIA/UART/<Pn>.Baudrate=0|1|2|3|4|5|6|7
Parameters
.Baudrate
0
1
2
3
4
5
6
7
BAUD rate value
4800
7200
9600
14400
19200
38400
57600
115200
Example
> SET/MEDIA/UART/P1.Baudrate=2
< pw/MEDIA/UART/P1.Baudrate=2
8.7.3. Databit setting
Command format
SET/MEDIA/UART/<Pn>.DataBits=8|9
Response format
pw/MEDIA/UART/<Pn>.DataBits=8|9
Example
> SET/MEDIA/UART/P1.DataBits=8
< pw/MEDIA/UART/P1.DataBits=8
8.7.4. Stopbits setting
Command format
SET/MEDIA/UART/P1.StopBits=0|1|2
Response format
pw/MEDIA/UART/P1.StopBits=0|1|2
Parameters
.StopBits
0
1
2
Stopbit value
1
1,5
2
Example
> SET/MEDIA/UART/P1.StopBits=0
< pw/MEDIA/UART/P1.StopBits=0
8.7.5. Parity setting
Command format
SET/MEDIA/UART/<Pn>.Parity=0|1|2
Response format
pw/MEDIA/UART/<Pn>.Parity=0|1|2
Parameters
.Parity
0
1
2
Parity setting
no parity
odd
even
Example
> SET/MEDIA/UART/P1.Parity=0
< pw/MEDIA/UART/P1.Parity=0