Page 4.2
Section 61
09.04
4.2.5.6 PRESSURE EQUALITY AND START OF CONTROL
TEST CONDITIONS
- Truck not jacked up.
- Pedals properly adjusted.
- Brake released.
- Engine and travel drive at operating temperature.
4.2.5.6.1 FUNCTIONAL TEST
- Driver seated on driver's seat
- Start engine
Test Symptoms Beurteilung
Sensitively depress F or Truck starts slowly Start of control okay.
R accelerator pedal without jerking.
(fine control range)
until truck starts. Truck jerks. Start of control not okay
Perform troubleshooting
acc. to following procedures.
4.2.5.6.2 TROUBLESHOOTING
- Jack up and secure the truck so that both traction wheels can rotate freely.
- Remove the front cover.
- Remove the floor plate.