5.8 Auto Conguration Function
Auto-Conguration is the function that automatically determines the
conditions of communication through a communication channel. It is
useful to measure the target devices with unknown communication
conditions.
This function is not 100% correct because the communication conditions of
devices varies. Please use the result as one sample.
Touch “ ” in the bottom left
and select “Auto conguration”.
Measurement will start after
setting the communication
conditions (speed, data
length, parity) of line monitor
automatically. To cancel this
operation, touch [Cancel] or press
[Esc] key.
Range of auto-conguration setting
Speed (bps)
50
460.8Kbps
Bit length
7 or 8 bits
Parity bit
None, Even, Odd
Speed will the one which is pre-set in the line monitor.
→ 3.3 Communication Speed
Stop bit is set to be “1” for monitoring.
Conditions to have a right auto-conguration
Several data are found in the communication lines.
There is not any error in the communication lines.
Data includes “101” or “010” of bit pattern.
-42-

Table of Contents

Other manuals for LineEye LE Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LineEye LE Series and is the answer not in the manual?

LineEye LE Series Specifications

General IconGeneral
BrandLineEye
ModelLE Series
CategoryMeasuring Instruments
LanguageEnglish