D9U001GE4-0101_0514
WARNING!
During specic investigations or treatments the signicant risks of reciprocal interference posed by ME equip-
ment may occur.
► Follow the instructions carefully.
► Use the bed exclusively if it is in perfect working order.
► If necessary, check the bed functions daily or at each shift change.
► Ensure any user has read and understood this manual completely before operating the product.
► Use the bed exclusively with the correct mains supply.
► Ensure that the bed is operated exclusively by qualied personnel.
► Ensure that the patient (health permitting) has been informed about the operation of the bed and all applicable safety
instructions.
► Move the bed exclusively on even, hard-surfaced oors.
► Replace any damaged parts immediately with original spare parts.
► Ensure that maintenance and installation are performed exclusively by qualied personnel who have been trained by the
manufacturer.
► During peak loads or unavoidable excess loads (CPR), place Mattress support platform in the lowest position.
► Ensure that only one adult patient uses the bed at any time.
► Take care to avoid injuries or squeezing when operating moving parts.
► When using lifting poles or infusion stands, ensure that nothing will be damaged when you move or adjust the bed.
► Brake the castors when the bed is occupied.
► Keep the mattress support platform in the lowest position at any time when the healthcare personnel are not treating the
patient in order to prevent the patient from falling or injuries.
► Enable or disable functions on Patient Control Panels using the iBoard Standard Attendant Control Panel as appropriate
for the patient’s physical and mental state. Verify that the function is actually disabled.
► Ensure that siderails are operated exclusively by healthcare personnel.
► Never use the bed in areas where there is a hazard of explosion.
► Never handle the mains plug with wet hands.
► Disconnect the product from the mains exclusively by pulling the mains plug.
► When pulling the mains plug, always hold the plug, not the cable.
► Position the mains cable so that there are no loops or kinks in the cable; protect the cable from mechanical wear and tear.
► Improper handling of mains cable can cause an electric shock hazard, other serious injuries or damage to the mattress
replacement system.
► Ensure that the stipulated duty cycle of motor is not exceeded.
► To change fuses or cables contact servise organisation authorized by manufacturer.
► Ensure that the moving parts of the bed are not blocked.
► To prevent failures, use exclusively the manufacturer’s original accessories and mattresses.
► Ensure that the stipulated safe working load is not exceeded.
► If the patient‘s condition could lead to an entrapment, leave the mattress support platform in the at position whilst
unattended.
► Adjust bed height when transporting the bed in order to facilitate overcoming possible obstacles.
► Do not exceed maximum load of 80 kg for bed extension.
► Do not modify bed and its components without the manufacturer´s approval.
► Use the mattress system exclusively as specied in this manual and in perfect working order.
► Use the mattress system exclusively with the correct mains supply (see Electrical Specications).
► Use the mattress system exclusively in its original state and do not modify it in any way.
► Have the mattress system used exclusively by or under supervision of trained and qualied nursing personnel.
► Have the mattress system serviced and installed exclusively by qualied personnel trained and authorised by the
manufacturer.
► Do not exceed the maximum patient weight limit (see Mechanical Specications).
► Do not use the SCU near ammable gases. (This does not apply to oxygen cylinders.)
► Do not hang anything on any cable.
► Never use the mattress replacement system near radiators or other heat sources.
► Never cover the SCU while in use.
► Select a suitable location for the placement of bed accessories and other objects to prevent involuntary activation of
buttons or controls which may result in the adjustment of bed positioning.
► Do not use the bed in the event parts have been removed (e.g. parts of mattress support platform) unless these parts are
designed to be removed (e.g. head and/ or foot end of the bed).
► Never place any accessories or handset on the siderails where keyboards are located.
► After each emergency situation always check if any of the controllers (in side rails, handset or ACP) is not involuntarily
pressed by the bed accessories or by the mattress.
► The weighing system must be calibrated at regular intervals and in accordance with the metrological regulations of the
relevant country. All testing and certication must be carried out by qualied personnel. The healthcare provider is
responsible for ensuring the required testing frequency and testing procedure of the weighing system is carried out.
► To avoid injury or crushing, take extra caution when operating any moving parts of the bed.
► To avoid unintended activation of moving parts during any use of the bed always check that none of the control elements
of the bed is not involuntary pressed by persons, mattress or other objects.