Stromlaufplan/schematic/Схематический
- 325 -10.13
Pos. order no.
A 1 650.5445.5
E-Baugruppe M-ControlBasic (E) pc-board M-ControlBasic (E) ɗɥɟɤɬɪɨɧɧɚɹɩɥɚɬɚ0&RQWURO%DVLF(
A 1 650.5445.9
E-Baugruppe M-ControlBasic (T) pc-board M-ControlBasic (T) ɗɥɟɤɬɪɨɧɧɚɹɩɥɚɬɚ0&RQWURO%DVLF7
A 2
650.5452.5
E-Baugruppe M-Bedienfeld Basic (E) pc-board M-control panel Basic (E) ɗɥɩɥɚɬɚ0ɉɚɧɟɥɶɭɩɪɚɜɥɟɧɢɹ%DVLF(
A 2
650.5452.9
E-Baugruppe M-Bedienfeld Basic (T) pc-board M-control panel Basic (T) ɗɥɩɥɚɬɚ0ɉɚɧɟɥɶɭɩɪɚɜɥɟɧɢɹ%DVLF7
A 3 658.0231.0
Gleichrichter B6 3P 8D 100x250
rectifier B6 3P 8D 100x250
ȼɵɩɪɹɦɢɬɟɥɶ%3'[
A 4 650.5448.5
E-Baugruppe M-BCD-Schalter (E) pc-board M-BCD-switch (E) ɗɥɟɤɬɪɨɧɧɚɹɩɥɚɬɚ0%&'6FKDOWHU(
F 1 - Thermoschalter auf T1 thermal switch (at T1)
Ɍɟɪɦɨɜɵɤɥɸɱɚɬɟɥɶɧɚ7
F 2 709.2001.0
Feinsicherung 2,5 A 500V TR 6,3x32mm fuse 2,5 A 500V TR 6,3x32mm ɉɪɟɞɨɯɪɚɧɢɬɟɥɶ$975[PP
F 4 709.2001.0
Feinsicherung 2,5 A 500V TR 6,3x32mm fuse 2,5 A 500V TR 6,3x32mm ɉɪɟɞɨɯɪɚɧɢɬɟɥɶ$975[PP
F 5 709.0153.0
Feinsicherung 1,0 A TR 5x20 fuse 1,0 A TR 5x20 ɉɪɟɞɨɯɪɚɧɢɬɟɥɶ$75[
F 6 570.8054.0
Schutzleiterüberwachung 6² 10A M5 Minif. protective earth monitoring 6qmm 10A M5 Ʉɨɧɬɪɨɥɶɡɚɡɟɦɥɹɸɳɟɝɨɩɪɨɜɨɞɚ² 10A
K 1 659.0012.0
Schütz A042 22 3001 contactor A042 22 3001 Ʉɨɧɬɚɤɬɨɪ$
L 1 655.5533.0
Drossel WA 24000056 Inductor WA 24000056 Ⱦɪɨɫɫɟɥɶ:$
M 1
620.9305.0
Vorschubeinheit VE 21 TYP37 SF wire feed unit VE 21 TYP37 SF
Ȼɥɨɤɩɨɞɚɱɢ9(7<36)
M 2
665.5726.0
Axialventilator 172x38 axial fan 172x38 Ɉɫɟɜɨɣɜɟɧɬɢɥɹɬɨɪ[
Q 1
657.0204.0
Wippschalter 2pol. 20A 250V~ FS 6,3 switch 20A 250V~ FS 6,3 Ʉɭɥɢɫɧɵɣɩɟɪɟɤɥɸɱɚɬɟɥɶɩɨɥ$
Q 3 657.1005.1
Stufenschalter 12/- Stu.20A BCD 3Ph v.2 Step switch 12/- Stu.20A BCD 3Ph v.2 ɋɬɭɩɟɧɱɚɬɵɣɩɟɪɟɤɥɸɱɚɬɟɥɶɋɬɭ
R 1 665.0532.0
Nebenwiderstand 300A/48mV Shunt 300A/48mV ɒɭɧɬ$P9
S 1 - Brennertaster torch switch
.ɧɨɩɤɚɝɨɪɟɥɤɢ
S 2
657.8500.0
Taster 1-polig Schliesser 20mm grau pushbutton switch S.P. N.C. 20mm grey Ʉɧɨɩɤɚɩɨɥɧɨɪɦɚɥɶɧɨɪɚɡɨɦɤɧɭɬɵɣ
T 1 655.1744.0
Trafo WA 11000053 MP Transformer WA 11000053 MP Ɍɪɚɧɫɮɨɪɦɚɬɨɪ:$03
T 2
655.8050.5
Steuertrafo 230/400V 42V / 19V Länge 150 Control transformer 230/400V 42V / 19V ɍɩɪɚɜɥɹɸɳɢɣɬɪɚɧɫ999
X 1 661.7604.7
Netzkabel 4G1.5 CEE 16 3AE1FS Mains cable 4G1.5 CEE 16 3AE1FS ɋɟɬɟɜɨɣɤɚɛɟɥɶ*&(($()6
X 2 620.7116.0
Zentralbuchse 78mm SF Central socket 106mm SF ɐɟɧɪɚɥɶɧɵɣɪɚɡɴɟɦPP6)
X 3
665.7020.0
Einbau-Buchsenteil BEB 35-50 mm² insert sleeve BEB 35-50 ȼɫɬɪɨɟɧɧɵɣɪɚɡɴɟɦ%(%PP²
Y 1
665.3006.0
Magnetventil 24VDC 1/4" Schlauchanschl. solenoid valve 24VDC 1/4"-hose connectio ɗɥɟɤɬɪɨɦɚɝɧɢɬɧɵɣɤɥɚɩɚɧ
Bez. MatNr. Benennung designation Ɉɛɨɡɧɚɱɟɧɢɟ
Pos. order no.
A 1 650.5445.5
E-Baugruppe M-ControlBasic (E) pc-board M-ControlBasic (E) ɗɥɟɤɬɪɨɧɧɚɹɩɥɚɬɚ0&RQWURO%DVLF(
A 1 650.5445.9
E-Baugruppe M-ControlBasic (T) pc-board M-ControlBasic (T) ɗɥɟɤɬɪɨɧɧɚɹɩɥɚɬɚ0&RQWURO%DVLF7
A 2
650.5451.5
E-Baugruppe M-Bedienfeld Basic Plus (E) pc-board M-control panel Basic Plus (E) ɗɥɩɥɚɬɚ0ɉɚɧɟɥɶɭɩɪɚɜɥɟɧɢɹ%DVLF(
A 2
650.5451.9
E-Baugruppe M-Bedienfeld Basic Plus (T) pc-board M-control panel Basic Plus (T) ɗɥɩɥɚɬɚ0ɉɚɧɟɥɶɭɩɪɚɜɥɟɧɢɹ%DVLF7
Gleichrichter B6 3P 8D 100x250
rectifier B6 3P 8D 100x250
ȼɵɩɪɹɦɢɬɟɥɶ%3'[
/HJHQGH]X6WURPODXISODQ3XWWLQJRQHWRFLUFXLWGLDJUDPɈɛɨɡɧɚɱɟɧɢɹɧɚɫɯɟɦɟɩɨɞɤɥɸɱɟɧɢɹ
S00.0057.7-04
M-Pro 250 Basic Plus (C)
M-Pro 250 Control Pro (C)
Gleichrichter B6 3P 8D 100x250
rectifier B6 3P 8D 100x250
ȼɵɩɪɹɦɢɬɟɥɶ%3'[
A 4 650.5448.5
E-Baugruppe M-BCD-Schalter (E) pc-board M-BCD-switch (E) ɗɥɟɤɬɪɨɧɧɚɹɩɥɚɬɚ0%&'6FKDOWHU(
F 1 - Thermoschalter auf T1 thermal switch (at T1)
Ɍɟɪɦɨɜɵɤɥɸɱɚɬɟɥɶɧɚ7
F 2 709.2001.0
Feinsicherung 2,5 A 500V TR 6,3x32mm fuse 2,5 A 500V TR 6,3x32mm ɉɪɟɞɨɯɪɚɧɢɬɟɥɶ$975[PP
F 4 709.2001.0
Feinsicherung 2,5 A 500V TR 6,3x32mm fuse 2,5 A 500V TR 6,3x32mm ɉɪɟɞɨɯɪɚɧɢɬɟɥɶ$975[PP
F 5 709.0153.0
Feinsicherung 1,0 A TR 5x20 fuse 1,0 A TR 5x20 ɉɪɟɞɨɯɪɚɧɢɬɟɥɶ$75[
F 6 570.8054.0
Schutzleiterüberwachung 6² 10A M5 Minif. protective earth monitoring 6qmm 10A M5 Ʉɨɧɬɪɨɥɶɡɚɡɟɦɥɹɸɳɟɝɨɩɪɨɜɨɞɚ² 10A
K 1 659.0012.0
Schütz A042 22 3001 contactor A042 22 3001 Ʉɨɧɬɚɤɬɨɪ$
L 1 655.5533.0
Drossel WA 24000056 Inductor WA 24000056 Ⱦɪɨɫɫɟɥɶ:$
M 1
620.9306.0
Vorschubeinheit VE 42 TYP37 SF Feed unit VE 42 TYP37 SF
Ȼɥɨɤɩɨɞɚɱɢ9(7<36)
M 2
665.5726.0
Axialventilator 172x38 axial fan 172x38 Ɉɫɟɜɨɣɜɟɧɬɢɥɹɬɨɪ[
Q 1
657.0204.0
Wippschalter 2pol. 20A 250V~ FS 6,3 switch 20A 250V~ FS 6,3 Ʉɭɥɢɫɧɵɣɩɟɪɟɤɥɸɱɚɬɟɥɶɩɨɥ$
Q 3 657.1005.1
Stufenschalter 12/- Stu.20A BCD 3Ph v.2 Step switch 12/- Stu.20A BCD 3Ph v.2 ɋɬɭɩɟɧɱɚɬɵɣɩɟɪɟɤɥɸɱɚɬɟɥɶɋɬɭ
R 1 665.0532.0
Nebenwiderstand 300A/48mV Shunt 300A/48mV ɒɭɧɬ$P9
S 1 - Brennertaster torch switch
.ɧɨɩɤɚɝɨɪɟɥɤɢ
S 2
657.8500.0
Taster 1-polig Schliesser 20mm grau pushbutton switch S.P. N.C. 20mm grey Ʉɧɨɩɤɚɩɨɥɧɨɪɦɚɥɶɧɨɪɚɡɨɦɤɧɭɬɵɣ
T 1 655.1744.0
Trafo WA 11000053 MP Transformer WA 11000053 MP Ɍɪɚɧɫɮɨɪɦɚɬɨɪ:$03
T 2
655.8050.5
Steuertrafo 230/400V 42V / 19V Länge 150 Control transformer 230/400V 42V / 19V ɍɩɪɚɜɥɹɸɳɢɣɬɪɚɧɫ999
X 1 661.7604.7
Netzkabel 4G1.5 CEE 16 3AE1FS Mains cable 4G1.5 CEE 16 3AE1FS ɋɟɬɟɜɨɣɤɚɛɟɥɶ*&(($()6
X 2 620.7117.0
Zentralbuchse 86mm SF Central socket 86mm SF ɐɟɧɪɚɥɶɧɵɣɪɚɡɴɟɦPP6)
X 3
665.7020.0
Einbau-Buchsenteil BEB 35-50 mm² insert sleeve BEB 35-50 ȼɫɬɪɨɟɧɧɵɣɪɚɡɴɟɦ%(%PP²
Y 1
665.3006.0
Magnetventil 24VDC 1/4" Schlauchanschl. solenoid valve 24VDC 1/4"-hose connectio ɗɥɟɤɬɪɨɦɚɝɧɢɬɧɵɣɤɥɚɩɚɧ
((UVDW]VSDUHSDUWɁɁɚɩɚɫɧɵɟɱɚɫɬɢ
77DXVFKUHSODFHPHQWɈɈɛɦɟɧ
Lorch Schweißtechnik GmbH
ɉɪɚɜɚɡɚɳɢɳɟɧɵɫɨɝɥɚɫɧɨ,62
ɉɟɪɟɞɚɱɚɢɜɨɫɩɪɨɢɡɜɟɞɟɧɢɟɞɚɧɧɨɝɨɞɨɤɭɦɟɧɬɚɢɫɩɨɥɶɡɨɜɚɧɢɟɢɫɨɨɛɳɟɧɢɟɨɟɝɨ
ɫɨɞɟɪɠɚɧɢɢɡɚɩɪɟɳɟɧɵɛɟɡɫɩɟɰɢɚɥɶɧɨɝɨɩɨɥɧɨɦɨɱɢɹ
ɉɪɚɜɨɧɚɪɭɲɢɬɟɥɢɧɟɫɭɬɨɬɜɟɬɫɬɜɟɧɧɨɫɬɶɩɨɜɨɡɦɟɳɟɧɢɸɭɛɵɬɤɨɜ
ȼɫɟɩɪɚɜɚɡɚɳɢɳɟɧɵɜɫɥɭɱɚɟɜɵɞɚɱɢɩɚɬɟɧɬɚɪɟɝɢɫɬɪɚɰɢɢɨɛɪɚɡɰɚɦɨɞɟɥɢɢɥɢɤɨɧɫɬɪɭɤɰɢɢ
Schutzvermerk nach DIN 34 / ISO 160 16:
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung ihres Inhaltes nicht gestattet,
soweit nicht ausdrücklich zugestanden. Zuwiderhandlungen verpflichten zu Schadenersatz.
Alle Rechte für den Fall der Patenterteilung oder Gebrauchsmuster-Eintragung vorbehalten.
Copyright reserved ISO 160 16:
Copying of this document, and giving it to others and the use or communication of the contents thereof,
are forbidden without express authority. Offenders are liable to the payment of damages.
All rights are reserved in the event of the grant of a patent or the registration of a utility model or design.