Messages
- 51 -10.13
Code Error description Note Rectication
E02 Mains overvoltage Mains input voltage too high Check mains voltage
E03 Overcurrent Output current is too high / Perma-
nent short circuit
Inform Service
E04-1 Emergency STOP /
periphery fault (op-
tional)
PE conductor monitoring input
(Fault current to protective earth
conductor) / Emergency STOP
activated
Check connection of the
workpiece cable and
ground clip, check for
short-circuits between
welding wire and hous-
ing / Check emergency
stop chain
E04-2 Emergency STOP /
periphery fault (op-
tional)
Input gas monitoring / water pres-
sure switch activated
Depending on equip-
ment, please check inert
gas or cooling water
E06 Overvoltage Output voltage too high Inform Service
E07 EEProm checksum
error
Setting data faulty or missing Switch the equipment
off and on again
E08 Wire feed Too high power intake from wire
feed motor (Motor Over-Current)
Blow down torch pack-
age with pressured air
and check pressure on
wire feed rolls.
E09 Voltage-measuring Voltage measuring system defective Inform Service
E13 Temp. sensor error Thermal sensor not ready for opera-
tion
Inform Service
E14 Supply voltage internal supply voltage too low
(18V~ / 24V-)
Check mains voltages
E15 Power measuring Fault at power measuring Inform Service
E16 Supply voltage
motor and main
contactor
Internal supply voltage is too little
(42V~ / 60V-)
Check power supply
voltage
E17 Peripherie overload/
short circuit
Short circuit in torch or hose pack-
age, gas valve or feed line, wire
run key or line
Test alt. exchange the
connected torch
E18 Error conguration Faulty or wrong pc-board,
wrong software system played
Inform Service
Tab. 8: Messages