ELECTRICITY
122
547379EN
80 (08/03/2017)
Menu Traction Motor Setup Motor setup Mini display Maxi display Pitch Value
1.7.1 Armature I Low (A) Armature low current (A) 10 240 10 90
1.7.2 Field I Low (A) Field low current (A) 5 25 1 6
1.7.3
1.7.4 Field I Mid (A) Field mid current (A) 6 40 1 25
1.7.5 Armature I High (A) Armature high current (A) 260 500 10 400
1.7.6
1.7.7 Armature Resistance (mOhm) Armature resistance (mOhm) 0 255 1 13
1.7.8 Field Resistance (Ohm) Field resistance (Ohm) 0.25 2.50 0.01 1.26
1.7.9 Drive Proportional Gain Translation proportional gain 0 255 1 2
1.7.10 Drive Integral Gain Travel total gain 0 16 1 6
1.7.11
1.7.12 Brake Integral Gain Brake total gain 0 16 1 15
1.7.13 Speed Estimate Gain Speed estimated gain 0 2.50 0.01 1.5
Menu Traction BDI Check Battery Charge Mini display Maxi display Pitch Value
1.8.1
Select hour meter to display
1.8.2 Display Status Type Select type of status data to display On
1.8.3 Display Contrast Set contrast level standard display screen 0 127 1 On
1.8.4 FFD Indicator 1
Select indicator 1 to display for advanced
display screen
On
1.8.5 FFD Indicator 2
Select indicator 2 to display for advanced
display screen
On
1.8.6 Display Fault Messages Validate display of default messages EU
Menu Pump Personalities Properties (hydraulic functions) Mini display Maxi display Pitch Value
2.1.1 Pump I Max Pump max current (A) 50 500 10 350
2.1.2
2.1.3 Ramp Down Delay Ramp down time (S) 0.1 0.5 0.1 0.5
2.1.4 Pump Creep Speed Speed (%) 0 25 1 10