3 - 38
Ü
3000 HOUR -
PERIODIC MAINTENANCE - EVERY 3000 HOURS OF SERVICE OR 6 YEARS
IN ADDITION, CARRY OUT PERIODIC MAINTENANCE FOR 500 HOURS OF SERVICE AND 1000 HOURS OF SERVICE.
REPLACE Dry air filter safety cartridge
- To remove and refit the dry air filter cartridge, see: 3 - MAINTENANCE: D3 - DRY
AIR FILTER CARTRIDGE.
- Remove the safety cartridge 1 of the dry air filter very carefully, to reduce leakage
of dust to the minimum.
- Carefully clean the seat of the filter gaskets with a wet clean cloth that does not
leave lint.
- Before the assembly, check the state of the new safety cartridge (see:3 -
MAINTENANCE: FILTER ELEMENTS AND BELTS).
- Insert the cartridge in the filter and position it by pressing on the edge of the filter,
not in the center.
NOTE: The safety cartridge replacement frequency is purely indicative. It must be replaced every three replacements of
the dry air filter cartridge.
649100 EN-US-AU (20/05/2019)
MLT 961-145 V PLUS L JD ST4 S1