2 - 42
EXHAUST PARTICLE FILTER REGENERATION
DISABLE AUTOMATIC REGENERATION
“STATIONARY TELEHANDLER” REGENERATION
e
MAINTENANCE: I2 - “STATIONARY TELEHANDLER” EXHAUST PARTICLE FILTER)
DISABLE AUTOMATIC REGENERATION
t
IMPORTANT
t
Disabling automatic regeneration of the exhaust particle filter is a function that is only to be used in case of necessity (confined or unventilated space, etc.).
By default, exhaust particle filter automatic regeneration is enabled each time the telehandler is started.
- To disable automatic regeneration of the exhaust particle filter, hold down the bottom of the switch. The temporary
display of the screen
and an audible beep followed by the screen on the operating display confirm
that it has been disabled.
- To re-enable automatic regeneration of the exhaust particle filter, hold down the bottom of the switch again. The
temporary display of the screen
and an audible beep confirm that it has been re-enabled.
MANAGEMENT OF EXHAUST PARTICLE FILTER REGENERATION
INDICATIONS ACTIONS
+ 1 short beep
Moderate soot level.
The screen appears on the operating display, the switching on of the indicator light
and the speeding up of the engine idling speed indicates that automatic regeneration
is in progress.
NOTE: Preferably wait until automatic regeneration is completed before switching off the ignition.
+ 1 short beep
Moderate soot level, automatic regeneration disabled.
Enable automatic regeneration at the earliest possible time.
+ + 1 long beep
High soot level.
Reduced telehandler efficiency, only “stationary telehandler” regeneration can be performed
(E:
3 - MAINTENANCE: OCCASIONAL MAINTENANCE).
+ + 1 long beep
High soot level, automatic regeneration disabled.
+ + + 1 short beep
Very high soot level, particle filter clogged.
Reduced telehandler efficiency, shut down the telehandler and contact your dealer.