Grove Published 3-23-2020, Control # 654-04 6-19
GRT655/655L OPERATOR MANUAL LUBRICATION AND MAINTENANCE
6
Item
Lube Point
Description
Figure
No.
Approved
Lubricant
Lube
Capacity
Lube Interval Application
Axles
30 Differentials Figure 6-7 B
28.4 L
(30 qt)
Check level every 500
hours or 3 months.
Drain and fill every
4000 hours or 2 years.
NOTE: Lube level close enough to the hole to be seen or touched is not sufficient. It must be level with the hole.
When checking lube level, also check and clean housing breathers.
CAUTION: Use of non-approved lubricant may damage components and/or invalidate published lubricant intervals.
CAUTION: If the makeup amount is substantially more than 0.23 L (0.5 pt), check for leaks.
31
Planetary Hubs
and Wheel
Bearings
Figure 6-7 B
2.5 L
(5.3 pt)
Check level every 500
hours or 3 months.
Drain and fill every
4000 hours or 2 years.
Fill to oil level
indicated on axle hub.
CAUTION: Use of non-approved lubricant may damage components and/or invalidate published lubricant intervals.
FIGURE 6-7
9030-6
31
31
30
31

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GRT655L and is the answer not in the manual?

Manitowoc Grove GRT655L Specifications

General IconGeneral
BrandManitowoc
ModelGrove GRT655L
CategoryConstruction Equipment
LanguageEnglish

Related product manuals