Matrox Solios GigE acquisition section 91
You can set the type of signal to route to an output auxiliary signal, or auxiliary
I/O signal in output mode, using the MIL-Lite function MdigControl() with
M_AUX_SIGNAL_SOURCE+n, where n is a value between 6 and 17.
User-defined 0Inx
1In x
2In x
3In x
4In x
5In x
6In/Out x
7In/Out x
8In/Out x
9In/Out x
10 Out x
11 Out x
12 Out x
13 Out x
14 Out x
15 Out x
16 Out x
17 Out x
Type of
signal
Signal number
In/Out
OPTO aux. in LVDS
aux. in
TTL aux. I/O TTL aux. out
AUX(TRIG)_OPTO_IN0
AUX(TRIG)_OPTO_IN1
AUX(TRIG)_OPTO_IN2
AUX(TRIG)_OPTO_IN3
AUX(TRIG)_LVDS_IN4
AUX(TRIG)_LVDS_IN5
AUX(TRIG)_TTL_IO_6
AUX(TRIG)_TTL_IO_7
AUX(TRIG)_TTL_IO_8
AUX(TRIG)_TTL_IO_9
AUX(EXP)_TTL_OUT10
AUX(EXP)_TTL_OUT11
AUX(EXP)_TTL_OUT12
AUX(EXP)_TTL_OUT13
AUX(EXP)_TTL_OUT14
AUX(EXP)_TTL_OUT15
AUX(EXP)_TTL_OUT16
AUX(EXP)_TTL_OUT17