9.0 SPECIFICATIONS
Power Source
AC 100-240 VAC / 45-66 Hz (20 W/25 VA) *
DC 10-35 VDC (21 W) *
* AC or DC must be specied at time of ordering.
Standard Outputs
Dual
4-20mA Outputs: Galvanically isolated and fully programmable for zero and full scale
(0-21mA rangeability)
Two
separate digital programmable outputs: open collector transistor usable for pulse,
frequency, or alarm settings.
• Volumetric Pulse
• Flow Rate (Frequency)
• Hardware Alarm
• High/Low Flow Alarms
• Empty Pipe
• Directional Indication
• Range Indication
• Maximum switching voltage: 40 VDC
• Maximum switching current: 100mA
• Maximum switching frequency: 1250 Hz
• Insulation from other secondary circuits: 500V
Optional Outputs
• Modbus
• HART
• Datalogger
• Smart Output
™
(Sensus, Itron 6, Itron 9)
• Built-in verification
Galvanic Isolation
All inputs / outputs are galvanically isolated from power supply up to 500 V
Engineering Units
• Cubic Meter
• Cubic Centimeter
• Milliliter
• Liter
• Cubic Decimeter
• Decaliter
• Hectoliter
• Cubic Inches
• US Gallons
• Imperial Gallons
• Cubic Feet
• Kilo Cubic Feet
• Standard Barrel
• Oil Barrel
• US Kilogallon
• Ten Thousands of Gallons
• Imperial
Kilogallon
• Acre Feet
• Megagallon
• Imperial
Megagallon
• Hundred Cubic
Feet
• Megaliters
Conductivity
Minimum conductivity of 5µS/cm
Electrical Connections
• Quick-Connect (IP68)
• Compression gland seals for 0.24” to 0.47” diameter round cable
• Conduit option: 1/2” NPT threaded connections