5.2 Menu 2 - Units
Menu
Position
Converter Function Code
Function
Name
Function Description
Access
Level
MCP
Command
2.1
[Diam.= mm]
Diameter Sets the sensor diameter unit of
measurement: mm or inch.
AL2 [SDIUM]
2.2
[S.Cable= m]
S.cable
length unit of
m. type
Sets the sensor cable length for
separate version. Select m or ft.
AL2 [SCAUM]
2.3
[FR unit= METRIC]
Flow rate unit
of m. type
Sets the ow rate type measurement
unit. Select metric or Imperial units.
AL2 [FRMUT]
2.4
[PL1 unit=
METRIC]
Pulse 1 unit
of m. type
This function is active with selection
7.1. It changes the measurement unit
in selection 3.2.
Pulse 1 type measurement unit:
Metric or Imperial units.
AL2 [PL1UT]
2.5
[PL2 unit=
METRIC]
Pulse 2 unit
of m. type
This function is active with selection
7.2. It changes the measurement unit
in selection 3.4.
Pulse 2 type measurement unit:
Metric or Imperial units.
AL2 [PL2UT]
2.6
[T+ unit= METRIC]
Totalizer+
unit of m.
type
Sets the total direct totalizer
measurement unit type: Metric or
Imperial units. This function changes
the measurement unit in selection
2.7.
AL2 [TTPUT]
2.7
[T+ unit= dm³]
Totalizer+
unit of
measure
Sets the total direct totalizer
measurement unit.
AL2 [TTPUM]
2.8
[T+ D.P.= x]
Totalizer+
Decimal
Point pos.
Sets the total direct totalizer decimal
point position.
Example:T+D.P.= 3 visualized
valueT+dm³0.000
T+D.P.= 2 visualized valueT+dm³0.00
AL2 [TTPDP]
2.9
[Temp.unit= C/F]
Temperature
unit of
measure
Sets the temperature measurement
unit.
AL2 [TMPUT]
2.10
[Mass units= ON/
OFF]
Mass units
enable
Enable or disable the selection of the
mass unit of full scale.
AL2 [MSSUE]