GASOLINE ENGINES BRAVO MODELS
Page 27 of 116
RPM REV-LIMITER
IMPORTANT: When selecting a propeller consider this additional information, if ap-
plicable:
The engines listed in the following chart are equipped with a rpm rev-limiter that is
set to an upper (or limited) rpm amount. This limit is slightly above the normal operat-
ing range of the engine and is designed to help prevent damage from excessive en-
gine rpm. Once the rpm drop into the recommended operating rpm range normal en-
gine operation resumes.
Engine Rev-Limiter
Model
Engine Recommended Operating
RPM Range
Rev-Limit RPM Setting
4.3L
4.3LH
4.3L EFI
5.0L
4400-4800 4950
5.0L EFI
5.7L
5.7L EFI
MX 6.2L MPI 4800-5200 5350
7.4L MPI 4200-4600 4680
350 Mag MPI
454 Mag MPI
4600-5000 5080
502 Mag MPI
Hot Water Heater Installation Recommendation
IMPORTANT: When connecting a cabin heater or hot water heater, certain require-
ments must be met:
• Supply hose (from engine to heater) and return hose (from heater to engine)
MUST NOT EXCEED 5/8 in. (16 mm) I.D. (inside diameter).
• Make heater connections ONLY at locations indicated in the following informa-
tion.
• Refer to manufacturers’ instructions for complete installation information and
procedures.
• Do not reposition engine temperature switch; it must remain where installed by
factory.
CAUTION
Avoid a performance loss and/or possible engine damage. Engine coolant must
flow continuously from the engine intake manifold to the engine water circulating
pump. NEVER close-off or block the coolant flow to or from a heater.
All heater installations must be plumbed in series with the supply and return con-
nections.