IMPORTANT: Avoid using excessive hose when routing it to gear lube monitor. Hose
should be routed directly to oil reservoir in as straight a line as possible to avoid low
spots (traps) in the system.
CAUTION
Ensure hose is not kinked when connecting in the following step. If hose is kinked,
gear lube monitor will not function properly and damage to sterndrive unit could
occur.
3. Route hose to gear lube monitor and cut off excess hose. Connect hose and secure with
hose clamp. Secure hose with the J-Clip that is attached to the valve cover.
71991
75444
a
b
c
454 CID/7.4L and 502 CID/8.2L Models
a-Gear Lube Monitor
b-Hose
c-J-Clip on Valve Cover
75847
a
76230
a
262cid/4.3L With Single Piece Manifolds 305 CID/5.0L and 350 CID/5.7L Models
a-Gear Lube Monitor