Installation Cont.
Plug Connections Multigen 400V 50Hz 3P+N+E
N.B.: If your trolley is supplied without a plug on the power supply cable or the plug is to be replaced, ensure that the plug
is of the appropriate rating to correspond with the trolley data plate and that the conductors are connected to conform with
the table below.
Three Phase, Neutral and Earth
Phase R : Brown
Phase S : Black
Phase T : Black
Neutral N : Blue
Earth E : Yellow/Green
Cord set: (This will permit all of the functions of the Multigen to operate with the exemption of the heating elements in the
oven compartment.).
Single Phase, Neutral and Earth
Phase R : Brown
Neutral N: Blue
Earth E: Yellow/Green
Extended Cables Multigen 400V 50Hz 3P+N+E
:
Always avoid long cables. It is much safer to reposition the socket to a more appropriate location.