Page 16 Technical data
Product Manual / Mounting Instructions „Servo drives ARS 2320 FS, ARS 2340 FS and ARS 2360W FS“ Version 1.0
3 Product description
Please see documentation of the servo drives ARS 2302 FS – ARS 2310 FS
4 Technical data
4.1 General
Metronix part number
with FBA module
Metronix part number
with STO module
Metronix part number
with MOV module
Ambient conditions and qualification
Admissible temperature ranges
Operating
temperature:
(Ambient)
0°C to +40°C
+40°C to +50°C with power reduction 2.5%/K
Max.
temperature of
coldplate:
50 °C (Only for ARS 2360W FS)
Admissible installation height
Mounting height maximum 2000 m above msl, from 1000 m above
msl with power reduction 1% per 100 m
Relative humidity up to 90%, no bedewing