Page 34 Mechanical installation
Product Manual / Mounting Instructions „Servo drives ARS 2320 FS, ARS 2340 FS and ARS 2360W FS“ Version 1.0
7 Mechanical installation
7.1 Important notes
Only use the servo drive ARS 2300 FS as a built-in device for switch cabinets with IP54
Mounting position vertical with supply lines [X9] on top
Mount to control cabinet plate using the mounting holes on top and bottom
Installation free spaces:
Keep a minimum distance of 100 mm to other components each above and underneath the device to
ensure sufficient venting.
For optimal wiring of the motor cable and angle encoder cable on the bottom of the device an
installation free space of 150mm is recommended!
Mounting distance:
The servo drives ARS 2300 FS may be installed adjacently in one switch cabinet without a gap,
proper usage and installation on a heat-dissipating rear panel provided. Please note that excessive
heat may cause premature aging and/or damaging of the device. In case the servo drives are subject
to high thermal stress, a mounting distance of 10 mm between two ARS 2300 FS is recommended!