Page 74 Electrical installation
Product Manual / Mounting Instructions „Servo drives ARS 2320 FS, ARS 2340 FS and ARS 2360W FS“ Version 1.0
Recommended cable type or comparable:
Cat.6 Patchkabel RJ45 LAN Kabel S-FTP/PIMF
8.13 USB communication [X19]
The ARS 2300 FS servo drive comprises a USB (universal serial bus) communication interface, which is
for connection via PC and for using the parameterisation tool Metronix ServoCommander
®
The USB communication interface requires no auxiliary power supply.
For the correct operation is a short USB cable (<3m) and a correct installation and earthing the servo
drive required. Should it nevertheless gets problems with hanging communication by strong disturbances,
the USB plug can briefly deducted to rebuild the communication.
In the case of non-EMC-compliant wiring of servo drive and motor, it can lead to
balancing currents via the connected computer and the USB interface. This can lead to
problems with the communication.
To avoid this, we recommend the use of the galvanically isolated USB adapter "Delock
USB Isolator" (Type 62588 from Delock) or one comparable adapter.
Figure 36: Pin assignment: USB interface [X19]