XTreme-EMS Operating Manual Page 37
FILTER:
This function can be used to select the signal filter time constant. Selections are "NONE", “FAST” or “SLOW”. This
selection influences the rate at which your manifold pressure can change its reading.
MAP CALIBRATION FACTOR:
The sender in the RDAC is shipped uncalibrated. To calibrate the manifold pressure, compare and adjust the calibration
factor until the manifold reading is the same as the pressure value in brackets. The pressure value in brackets is the
barometer reading built into the Xtreme. The manifold pressure can only be calibrated in mB.