Page 48
2D/3D Output Unit
scanCONTROL 30xx
7. 2D/3D Output Unit
The measurement system scanCONTROL 30xx measures and evaluates 2D profile data of a surface and supplies analog and digital
control signals. 2D/3D Output Unit
- outputs digital and analog signals,
- is based on the WAGO®-I/O-System 750,
- uses Ethernet.
Setup and operation of 2D/3D Output Unit are exemplarily described below.
7.1 2D/3D Output Unit - Components
- Output Unit Basic, consisting of:
Ethernet Fieldbus Coupler with system supply unit (OU-Fieldbus Coupler/Ethernet)
24V DC power supply filter (OU-Filter module) and termination module (OU-Bus termination module)
- Digital output terminal
- Analog output terminal
+
+
-
13
14
C
D
B
A
750-626
+
+ Ñ
-
-
Power contacts
Supply via power
contacts
24V
Status of
voltage supply
- Power contacts
- System
Data contacts
System supply (OUT)
24 V
0 V
0 V
System supply (In)
24 V
0 V
C
D
B
A
750-600
OU filter module
Bus terminationAnalog output terminal
253-057
LINK
ACT
MS
I/O
ETHERNET
NS
87654321
NO
LINK
ACT
1
2
X
1
X
2
8
1
ON
24V
X3
0V
0: WBM
255: DHCP
OU fieldbus coupler
A1 A2
13 14
750-536
A3 A4
A5 A6
A7
A8
DO 2
Power contacts
Data contacts
DO 2
Status
D0 4
D0 6
DO8
DO 8
Digital output terminal
DO 1
Status
DO 7
DO 7
DO 1
DO 5
DO 3
A1
A2
13 14
C
D
B
A
M
M
A3 A4
M M
750-555
AO 2
AO 1
AO 4
AO 3
V
0
V
0
V
0
V
0
Power contacts
Data contacts
Function
Error
Fig. 26 Example configuration Ethernet with analog and digital output module