S t a n d B y
Fig. 6 - Display message during stand-by mode (Master sets).
S t a n d B y
Fig. 7 - Same message on a slave unit. Slave mode requires an established connection to the master and
both the slave and the master have to be plugged to the mains supply.
While in stand-by mode, an EBC will neither circulate the air between case and EBC, nor will it start/continue
with any pumping, humidifying or dehumidifying processes. Also no data will be logged or provided live on
the RS232 interface at this stage. Previously recorded data can be read out during stand-by, though, and the
menu on the EBC's front panel is accessible, too (see section 4.5 "Settings and read-outs - working with the
menu", p. 25).
4.4 Switching on and off
IMPORTANT: An EBC should not be moved once it has been set into operation. Also, after having
switched off again, always wait for the completion of the possibly following final pump process before moving
or unplugging the unit.
Push the On-Off/Reset button for about a second to set the device into operation. Slave sets are switched
automatically with the master, they can neither be switched on nor off separately.
Depending on the actual settings and the values in the case the unit (or chain of units) will immediately
switch into the respective mode of operation, and so the message on the display of the master unit can now
be one of these ("50%" being an exemplary value):
5 0 % H u m i d i f y
5 0 % D e h u m i d i f y
5 0 % I n R a n g e
Fig. 8 - Possible display messages during normal operation (Master sets).
The humidity value displayed to the left resembles the actual humidity in the case as measured by the
miniClima RH/T sensor.
EBCs used as slave units will always copy the display of the chain's master unit, except for an arrow symbol
Applies analogously to the individual products of series EBC10/11/12 (Rev.3). As of 24.11.2014. Subject
to modification.
miniClima - Manual_EBC10-11-12(Rev.3)_en