miniClima Schönbauer GmbH
Brunner Str. 21b, 2700 WIENER NEUSTADT, AUSTRIA, EU
Tel. | Phone: +43 2622 24964, +43 6991 24964 01, Voicemail: +43 6993 24964 01, Fax: +43 2622 24964 15, E-Mail: office@miniclima.com
www.miniclima.com, twitter.com/miniClima, www.linkedin.com/company/miniclima-schönbauer-gmbh, www.google.com/+Miniclima, www.facebook.com/miniclima
UID | VAT-ID: ATU61994435, EORI: ATEOS1000001229, DVR: 4008782
Firmenbuchnummer | Trade Register Number: 267137z (Landesgericht | Regional Court of Wiener Neustadt)
EBC12 - device for air volumes of up to approx. 10m
3
.
NOTE: The capacity of an EBC will differ depending on the ambient conditions, the tightness and
constitution of the case, the tightness and constitution of the connections between case and device, the kind
and consistency of the materials stored/presented inside the case, and the like.
Every EBC of the current series can be used as both a master unit and a slave. The decision for one of the
two hierarchic states is selected automatically dependant upon the type of cable connected to the EBC. If it
is the cable of a miniClima RH/T sensor then the EBC becomes a master controller; if it is the control line
coming from another EBC then the unit becomes a slave and will duplicate the function of the EBC that is the
first in the line (chain of EBCs).
With this it is possible to increase the max. volume of the air that can be conditioned: Every added EBC10
increases the capacity by approx. 3m
3
, every added EBC11 by about 5m
3
and every added EBC12 by about
10m
3
. Mixing different types of EBCs (EBC10, EBC11, EBC12) within one chain is permissible. Furthermore
it does not matter which of those types is going to be used as the master of the chain and which as slave(s).
2 IDENTIFYING YOUR UNIT AND ITS ACCESSORIES/OPTIONS
2.1 Delivered items (per EBC)
1 EBC.. (packed extra in order to avoid transport damages: 1 6pin plug-in connector).
1 Water bottle, 0.5l (default for EBC10/11) or 2.0l (option for EBC10/11, default for EBC12).
1 Flexible hosepipe (length as ordered or by default 3m for each EBC10, 5m for each EBC11 and 6m for
each EBC12).
2 Hosepipe fittings for affixing the hosepipes to the case. Depending on the make
2
each hosepipe fitting
consists of 1 connector, 1 counter nut, 1 gasket ("GD.."), 1 slotted clamping ring
3
, 1 union nut
4
.
1 Mains connection cable (1.8m) with plugs on either side.
Either (for EBCs sold as master units): 1 RH/T sensor with housing, cable (2.5m resp. 5.0m), RJ45 plug
and a ferrite core ( IMPORTANT: Please see the printed note that has been added your delivery before
handling the sensor). Usually packed with the sensor: 1 free clip and screw for mounting the sensor.
Or (for EBCs sold as slave units): 1 control line (2.0m resp. 5.0m; category-5e patch cable, twisted
pair/non-crossed, with RJ45 plugs and ferrite cores on either end).
2
Current models are shipped with fittings of type 3 ("VE.._V3"). Type 2 (and partly its predecessor type 1) is still available, though.
3
Type 1 only ("VE.._V1").
4
Type 1 and type 2 only ("VE.._V1" and "VE.._V2").
Applies analogously to the individual products of series EBC10/11/12 (Rev.3). As of 24.11.2014. Subject
to modification.
miniClima - Manual_EBC10-11-12(Rev.3)_en