EasyManua.ls Logo

miniClima EBC - Pump Alarm

Default Icon
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
miniClima Schönbauer GmbH
Brunner Str. 21b, 2700 WIENER NEUSTADT, AUSTRIA, EU
Tel. | Phone: +43 2622 24964, +43 6991 24964 01, Voicemail: +43 6993 24964 01, Fax: +43 2622 24964 15, E-Mail: office@miniclima.com
www.miniclima.com, twitter.com/miniClima, www.linkedin.com/company/miniclima-schönbauer-gmbh, www.google.com/+Miniclima, www.facebook.com/miniclima
UID | VAT-ID: ATU61994435, EORI: ATEOS1000001229, DVR: 4008782
Firmenbuchnummer | Trade Register Number: 267137z (Landesgericht | Regional Court of Wiener Neustadt)
application/installation/handling.
Broken case sealing/unqualified case. Please get in touch with the manufacturer/distributor of your case.
Chosen setpoint is too ambitious - see section 9 "Technical data", p. 53.
Due general service or faulty device - see section 7 "Maintenance and care", p. 47.
5.2 Pump alarm
5 0 % P u m p
5 0 % A L A R M
Fig. 25 - Display message for the pump alarm. The words "Pump" and "ALARM" light up rotationally.
5.2.1 Description of the alarm
The EBC's water handling system is troubled or broken, and the water can not be transported in and/or out
of the EBC anymore, or the intern sensor detects water where there should not be some (anymore). In order
to protect the pump from overheating the unit will block the pump until the alarm has been reset. The alarm
might also be set back automatically once the intern sensor has dried up (i.e. if the alarm came because the
unit was been moved during operation).
5.2.2 Remaining EBC functions during this alarm
Humidify: Not unconditionally
Dehumidify: Not unconditionally
Air circulation between case and EBC: Yes
Pump: Not unconditionally
Fan(s) for the device cooling: Yes
Slave control: Yes (succeeding slaves continue to work normally - includ. humidification and
dehumidification)
5.2.3 Possible reasons and solutions
Please investigate in the outlined order:
1) At first try whether resetting (short push on On-Off/Reset) resolves the problem lastingly. If not continue
as follows.
Applies analogously to the individual products of series EBC10/11/12 (Rev.3). As of 24.11.2014. Subject
to modification.
miniClima - Manual_EBC10-11-12(Rev.3)_en
40 / 54

Table of Contents