miniClima Schönbauer GmbH
Brunner Str. 21b, 2700 WIENER NEUSTADT, AUSTRIA, EU
Tel. | Phone: +43 2622 24964, +43 6991 24964 01, Voicemail: +43 6993 24964 01, Fax: +43 2622 24964 15, E-Mail: office@miniclima.com
www.miniclima.com, twitter.com/miniClima, www.linkedin.com/company/miniclima-schönbauer-gmbh, www.google.com/+Miniclima, www.facebook.com/miniclima
UID | VAT-ID: ATU61994435, EORI: ATEOS1000001229, DVR: 4008782
Firmenbuchnummer | Trade Register Number: 267137z (Landesgericht | Regional Court of Wiener Neustadt)
2) Turn the EBC off (by pushing and holding On-Off/Reset for about a second). Slaves are switched
automatically with their master. Wait for the completion of the pump process (if any), then (
IMPORTANT) pull the mains plug. Check whether you can spot puddles or drops of water on the outside
close around or underneath the EBC, which are not caused i.e. by having handled the bottle unwarily,
and/or whether you can spot any leaks on the bottle or on the outside part of the silicone pipe. If the bottle
and/or the silicone pipe are damaged, make a photo of the pipe/the bottle and send it to
<office@miniclima.com> along to your contact data and a brief description of the problem. Leave the EBC
plugged off meanwhile and do not use it yet. We'll be getting in touch asap to discuss the next steps.
Should both the bottle and the pipe be in order but still some water, which you think has come out of the
EBC, is found outside the EBC, so please make a photo of this and send it to <office@miniclima.com>
along to your contact data and a brief description of the problem. Leave the EBC plugged off meanwhile,
not yet using it again. We'll be getting in touch asap to discuss the next steps. If none of the above has
applied, continue with the next step, leaving the EBC turned off and pulled from the mains.
3) Check the water level in the bottle and whether the silicone pipe reaches to the bottom of the bottle. If the
end of the pipe is not under water, put it inside. Plug your EBC back on and restart it (long push on On-
Off/Reset). The unit will be pumping again and should manage this time. If not, or if the pipe has been
and still is inside the bottle correctly anyway, and if also the bottle has been and still is filled correctly,
continue with the next step.
4) Plug the EBC back on and restart it. Listen whether you can hear the pump working now. If no sound from
the pump could be heard after the EBC had been switched on again, put the setpoint to a value well
above the currently measured RH level in the case (see section 4.5.1 "Menu entry " on p. 26; this setting
will not be needed for a long time, so no relevant changes to the relative humidity inside your case will be
made). If you still can not hear any sound from the pump over the next 10 seconds once the new setpoint
had been saved, then the EBC needs to be sent in - see section 8 "Deinstalling / packing up / storing /
shipping" on p. 51. If, on the other hand, the pump can be heard, put the setpoint back to your preferred
value and continue with the next step.
5) Turn the EBC off again. Slaves are switched automatically with their master. IMPORTANT: Pull the
mains plug. Loosen the screws that fix the cover of the EBC. Lift the cover ( CAUTION: Do not tear the
earthing wire!). Check whether one of the inside parts of the silicone pipe is kinked, so that no water
would be able to pass it. If yes, please make a photo of it and send it to <office@miniclima.com> along to
your contact data and a brief description of the problem. We'll be getting in touch asap to discuss the next
steps. Do close the cover in this case ( IMPORTANT: Take care to not squeeze any pipes or wires!), but
leave the EBC plugged off, not yet using it again. In case the pipe is not kinked, leave the cover open and
continue with the next step.
6) Check whether you can spot any puddles or drops of water on the inside at the bottom of the housing
Applies analogously to the individual products of series EBC10/11/12 (Rev.3). As of 24.11.2014. Subject
to modification.
miniClima - Manual_EBC10-11-12(Rev.3)_en