minutes. At continuous humidification, on the other hand, every EBC (as of processor version V121107.01) is
going to empty its intern tub completely every six hours, thus avoiding deposits being built up on the tub's
surface (mind to empty and clean the bottle in regular intervals - see further below).
In dehumidification mode (and, if cooling of the inner electronics is required, also during humidification mode)
a second fan inside the EBC (EBC10/11) or a pair of them (EBC12) will be turned on to cool the EBC's heat
sink(s) and inner parts. The cooling fan(s) is/are somewhat louder than the above-mentioned circulation fan
(see section 9 "Technical data" on p. 53). A warm air stream coming out from the cooling slits on the EBC's
cover and bottom can now be felt. The cooling air is sucked to the inside of the EBC on the unit's right-hand
(EBC12: right and left-hand) cooling air grill(s). All those passages for the cooling air (cover, bottom, right
and, where appropriate, left side) have to be kept clean and an edge distance of about 5cm shall be left from
any air grill on the side and from the slits on the cover.
NOTE: In case of a power outage (or when the mains connection has been cut in any other way), the EBC
will always return to the last mode it had been working in (Stand-by or humidity control) as soon as the
power supply becomes reestablished. Also, all settings that had been taken on the EBC will remain intact
despite of any power outage.
4.7 Controlling, feeding, emptying and cleaning the bottle
EBCs with sensors for both the water high mark and the water low mark will issue the corresponding alarm
as soon as it becomes necessary to alter the water level in the bottle (given the bottle is positioned and
maintained correctly). The water level in the bottles of all other EBCs should be controlled from time to time
(the interval depending on the overall conditions).
After some weeks or months of operation it might become necessary to clean the bottle of any unit, as dust
and particles from within the case will finally have been transported to the bottle. Deposits on the inside of
the bottle might also lead to a situation where the water level sensors are incapable of detecting the water
anymore.
NOTE: Do only use distilled water for the bottle, otherwise the EBC might need to be sent in for intern
cleaning ahead of time. Also, if uncertain, fill the bottle only halfway at first, so as to leave space for the
condensate that will be added to the distilled water in the bottle when the EBC is dehumidifying.
Proceed as follows to feed/empty/clean the bottle:
Applies analogously to the individual products of series EBC10/11/12 (Rev.3). As of 24.11.2014. Subject
to modification.
miniClima - Manual_EBC10-11-12(Rev.3)_en