A l a r m M a x 6 5 %
Fig. 13 - Display message in menu mode, 2nd menu entry.
4.5.2.1 Description/options
AlarmMax is the variable that can be altered with this menu entry; 65% (example) is the currently set value of
this variable (in %RH).
Press Menu/Esc once more to leave the menu mode without changing any values.
indicates that you can move up and down the menu to go to the next/previous menu entries by pressing
Up or Down. No changes will be made to the AlarmMax value by doing so.
indicates that this variable can be set by pressing Enter.
Press Enter to alter the value for AlarmMax (possible range: min. 5 points above the setpoint; max. 90%).
The two digits resembling the value on the display start to blink. Use the Up and Down buttons to make
your changes, and confirm the new value with Enter. The value will not be stored as long as you do not
press this button.
4.5.3 Menu entry AlarmMin
With this entry you can define a lower threshold value for the humidity alarm to go off (master units only). If
the relative humidity inside the case falls beyond this value and if it remains there for at least 30 minutes
(standard alarm delay), an alarm will be issued from your EBC. Depending on the settings taken via the
menu entry for the first alarm (see p. 30) the first humidity alarm can additionally be delayed for 1 to 99 days.
By default the AlarmMin value is usually stored 10 points below the value for the setpoint. The minimum
spacing required between AlarmMin and the setpoint is five points. Every time the setpoint is altered the
lower threshold value will be moved analogously to keep the same spacing that has been set before. If you
have, for instance, set a lower threshold value of 40% and you alter the setpoint from 50% to 55%, the value
for AlarmMin will be moved to 45% automatically. NOTE: If the setpoint is put to its lowest possible value
(15%), the distance to AlarmMin is automatically reduced to 5 points, as otherwise the lowest possible value
for AlarmMin (10%) would have been crossed. Once the difference came to rest at 5 points by this it will be
kept there - even if you chose a higher value for the setpoint shortly after. With a setpoint chosen high
enough, AlarmMin can of course be lowered again manually, though.
Press Menu/Esc to call up the menu, then press Up twice to move to the menu entry for the lower
Applies analogously to the individual products of series EBC10/11/12 (Rev.3). As of 24.11.2014. Subject
to modification.