threshold value (AlarmMin). The display reads:
A l a r m M i n 4 5 %
Fig. 14 - Display message in menu mode, 3rd menu entry.
4.5.3.1 Description/options
AlarmMin is the variable that can be altered with this menu entry; 45% (example) is the currently set value of
this variable (in %RH).
Press Menu/Esc once more to leave the menu mode without changing any values.
indicates that you can move up and down the menu to go to the next/previous menu entries by pressing
Up or Down. No changes will be made to the AlarmMin value by doing so.
indicates that this variable can be set by pressing Enter.
Press Enter to alter the value for AlarmMin (possible range: min. 10%; max. 5 points below the setpoint).
The two digits resembling the value on the display start to blink. Use the Up and Down buttons to make
your changes, and confirm the new value with Enter. The value will not be stored as long as you do not
press this button.
4.5.4 Menu entry AlarmBeep
With this entry you choose to be alarmed not only visually on the front panel of the EBC but also acoustically
by a beeper that is built into the EBC (masters and slaves likewise). With an issued alarm and an activated
beeper a clearly audible tone will be issued every three minutes by the EBC. The default setting for the
acoustic alarm is "Off".
NOTE: The three minutes interval is constantly counted down in the background, even if no alarm is due.
Therefore it can take up to three minutes before the beeper goes off for the first time after an alarm has been
prompted visually via the LED and the display. You can test the alarm sound by activating it as described
below and by then lifting the bottle up the upper water level sensor (turquoise plate), so that the water level
in the bottle is above the sensor. Wait for up to three minutes to hear the sound.
Press Menu/Esc to call up the menu, then press Up three times to move to the menu entry for the
acoustic alarm (AlarmBeep). The display reads: