MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 36
Code Function Factory Default Program Choices
*111 Enter 11 Digit Telephone Number Blank See worksheet 4 digit resident
code and up to 11
digit telephone
number
*202 Review, Delete Dial Codes & Blank See worksheet Up to 11 digits to
Telephone Number review or delete
*222 Enter Prefix (0) 0905 See worksheet 0-9 first digit and
up to 4 digit area
code
*303 Enter Keyless Entry Codes Blank See worksheet 4 digits
*333 Quit Feature using the “#” Key 11 __ __ 00 Press # key
once or
11 Press # key
twice
*404 Review and Delete Keyless Entry Blank See worksheet 4 digit code to
Codes review or delete
*444 Program On Line Timer for 00 __ __ 00 Seconds or
Minutes or Seconds 11 Minutes (2
digits)
*505 Change Master Code *999 *__ __ __ 3 digits
*606 Select Pulse(Rotary) or Tone 11 __ __ 00 Pulse or 11
Tone(DTMF) Tone (2 digits)
*707 Set Door Open Timer 10 seconds __ __ 00 to 99 seconds
seconds (2 digits)
*808 Set On Line Timer 60 seconds __ __ 00 to 99 (2 digits)
*909 Select MULTIPLE/SINGLE Multi 00 ___ ___ 00 for Multi or
Entrance 11 Single (2digits)
"NO MANUAL" MENU DRIVEN PROGRAMMING USING *888
Enter " *888 " to display a help menu.
The screen should appear...
1=Up 3=Down
#=Execute *= Quit
1 and 3 keys are used for scrolling up or down the feature menus.
# key is used to access the displayed feature.
* key is used for quit, exit, cancel, or abort.
Press 3 for next menu. The screen should appear...
To Exit PROGRAM
MODE - Press #
At this menu, pressing * will lead you to the PROGRAM MODE menu. Pressing # will exit to NORMAL MODE.
Press 3 again for next menu. The next screen should lead you to the first feature menu.