PLC User's Manual - Positioning Control Edition
Built-in Positioning Functions
6 Mechanical Zero Return - DSZR/ZRN Instruction
6.2 DOG Search Zero Return (DSZR Instruction)
B - 102
6.2.3 Function and Operation
 For details on the maximum speed, bias speed, acceleration time, and deceleration time, refer to
Subsection 4.2.5 to Subsection 4.2.8.
*1. X000 to X005 for FX
3S PLC.
1) For , specify the near-point signal (DOG) input device number. To specify the logic of this near-
point signal (DOG), turn the "DOG signal logic reverse" relay on or off as shown in the following table.
Detection of (the rear end and the front end of) the near-point signal (DOG) will be affected by the input
filter and the scan time of the sequence program.
Secure 1 scan time or more from the rear end of the DOG to turning ON of the zero-point signal.
Pulse output
destination device
"DOG signal logic
reverse" relay
Description
= Y000
M8345
OFF: Positive logic (Turning on the input will turn on the
near-point signal.)
ON: Negative logic (Turning off the input will turn on the
near-point signal.)
= Y001
M8355
= Y002 M8365
= Y003 M8375
Command
input
FNC150
DSZR
S
2
S
1
D
1
D
2
Maximum speed
Initial value: 100,000Hz
Zero return speed
Initial value: 50,000Hz
Deceleration
time
Bias speed
Initial value: 0Hz
Acceleration
time
Creep speed
Initial value:
1,000Hz
CLEAR signal
Zero-phase signal
(X000 to X007)
*1
1 ms or less
20 ms + 1 scan time (ms)
S2
Current value register = "0"
Initial value:
100 ms
Initial value:
100ms
DOG
S
1
Front endRear end
S
1
D
1
D
1
D
1
D
1